Skip to main content

Johns Hopkins

Johns Hopkins Pediatric

A New Concept for Neural Implants

May 31, 2018

Gene Fridman and Yun Guan investigate the idea of safe, implantable medical devices that use direct electrical current to block pain signals.

Johns Hopkins researchers say that recent experiments advance the search for implantable devices able to treat chronic pain from peripheral nerve injury or disease.

“We have developed a potential new concept for neural implants that works differently than conventional electrical stimulators,” says Gene Fridman, assistant professor of otolaryngology—head and neck surgery and biomedical engineering at the Johns Hopkins University School of Medicine. “We believe we are the first to investigate the idea of using this concept for implantable medical devices that use direct electrical current, long thought to be unsafe.”

Using computer models and laboratory rats, the team has demonstrated that “direct electrical current” can be delivered to nerves preferentially, blocking pain signals while leaving other sensations undisturbed. 

In a report on the new findings, published online April 11 in Science Advances, the researchers say direct electrical current devices would allow for more precise, preferential targeting of the appropriate pain-transmitting nerve cells, making them more effective for pain suppression and reducing the side effects of conventional devices. 

Traditionally, direct current—or single-direction streaming electrical signaling—has been considered unsafe for medical devices that deliver electrical stimulation in the body. The continual flow of electrical current results in chemical reactions at the site of the electrodes delivering the signal, causing gas bubbles, corrosion and toxic byproducts to form. 

All modern implantable electrical stimulation devices use alternating current pulses instead, in which the electrical current switches back and forth very quickly in a circuit between positive and negative voltage. Such rapid pulses allow the devices to interact with the nervous system but don’t create the toxic chemical reactions.

In 2013, Fridman and his team reported on successful efforts to develop an ionic direct current system, which converts the “safe” pulses like those delivered in the conventional stimulator into direct ionic current that may potentially be applied to the body safely.

To find out if the modified system of direct ionic current could be safely used to preferentially target and silence pain-transmitting neurons, Fridman teamed up with pain researcher Yun Guan, an associate professor of anesthesiology and critical care medicine and neurological surgery at the Johns Hopkins University School of Medicine. 

Fridman and Guan’s team first devised a computer model to try to predict what happens when researchers use direct current to block the pain signalsor inhibit other sensory neurons. In the model they sent negatively charged direct current to the nerves to weaken their activity. The model showed that the sodium channels 1.6 in the feeling sensory neurons were blocked with 670 microamperes, but the pain neuron’s sodium channels 1.7 were blocked at only 290 microamperes. For comparison, holding a 9-volt battery to the tongue delivers approximately 2,000 microamperes, causing a small shock. This suggested to the researchers that it was theoretically possible to preferentially target one type of neuron over another, since the channels could be blocked at different levels of current.

Next, working with anesthetized rats, they sent direct ionic current into the sciatic nerve in the legs and, using neural recording electrodes, recorded whether this current inhibited the activity of individual or groups of neurons at the spinal cord. 

 “Using direct current, we can inhibit the pain-transmitting neurons at much lower amplitudes than the feeling sensory neurons, allowing us to be preferential in how we target the nerve,” says Guan. “We also found that because the pain neurons take longer to come back on line, we may be able to conserve energy and not have to deliver this electrical current constantly to keep them blocked.” 

Being able to deliver this current periodically rather than constantly would mean longer use of the neural implant before needing to recharge the battery, says Guan.


© The Johns Hopkins University, The Johns Hopkins Hospital, and Johns Hopkins Health System. All rights reserved.

Powered by BROADCASTMED